Medical devicesElectronicsRoboticsAutomotive
TOKYO RIKOSHA CO., LTD.
A century of expertise in manufacturing power supply control devices such as Slide transformers, Noise Cut Transformers, integrated electrical safety testing systems and others
- Address
- 1-4-30 Sakawa, Saitama city, Saitama-Pref, Japan, 338-0823
- TEL
- +81-(0)48-856-3851
- Contact person
- President: Takanori Okazaki
- eigyou@tokyorikosha.co.jp
- Area of Business
- A century of expertise in manufacturing power supply control devices such as Slide transformers, Noise Cut Transformers, integrated electrical safety testing systems and others
Thyristor Type Single-Phase Power Regulator(Product name: VARITAP)
- Immediate disconnection fuses fitted as standard on all models
- Detect instantaneous power failures of the power supply
- Fuses are hard to blow at the primary control of the transformer
- Free power supply source of 100-240 V specifications
- Can be set using digital indicators
- Inductive load(during phase control) compatible
- Automatically switches frequencies
- With communication Function (RS-485 Models)
- CE marking certified(up to 100A)
- Detect instantaneous power failures of the power supply
- Fuses are hard to blow at the primary control of the transformer
- Free power supply source of 100-240 V specifications
- Can be set using digital indicators
- Inductive load(during phase control) compatible
- Automatically switches frequencies
- With communication Function (RS-485 Models)
- CE marking certified(up to 100A)
Noise Cut Transformer
Ultra-effective for noise
Shuts off abnormal voltages.
<Specifications>
Phase:Single phase, Two wires
Frequency:50/60Hz
Voltage:300VA-4KVA(100V,120V,200V,208V,220V,240V)
5KVA-10KVA(200V,208V,220V,240V)
- CE marking certified(NSCE series)EN64558-2-4
3KVA-10KVA has eyebolts
Most modern electronic equipment is semiconducting, and these semiconductor devices are susceptible to abnormal transmission caused by circuit opening and closing, which can lead to equipment breakdown or malfunction due to reduced temperature.
Noise-cut transformers and lightning transformers protect equipment by preventing damage to the equipment caused by over-voltages.
Shuts off abnormal voltages.
<Specifications>
Phase:Single phase, Two wires
Frequency:50/60Hz
Voltage:300VA-4KVA(100V,120V,200V,208V,220V,240V)
5KVA-10KVA(200V,208V,220V,240V)
- CE marking certified(NSCE series)EN64558-2-4
3KVA-10KVA has eyebolts
Most modern electronic equipment is semiconducting, and these semiconductor devices are susceptible to abnormal transmission caused by circuit opening and closing, which can lead to equipment breakdown or malfunction due to reduced temperature.
Noise-cut transformers and lightning transformers protect equipment by preventing damage to the equipment caused by over-voltages.
Useful integrated electrical safety testing system
Apparatus for detecting electrical faults
【Test Examples】
- Insulation endurance
- Protective continuity
- Leak current
- Power consumption (VA) measurement
- Other safety related test
【Test Examples】
- Insulation endurance
- Protective continuity
- Leak current
- Power consumption (VA) measurement
- Other safety related test
Slide transformer & various transformers for FFU
Company profile / business description
Electricity is the eternal Energy, Tokyo Rikosha Co., LTD. is improving technology with dreams.
Please download our company profile below:
PDF Download Please download our company profile below:
It’s possible to request a meeting with exhibiting companies through an inquiry